Monday, 23 April 2012

The New FLIR T400 Series with image enhancement


FLIR T400-Series




320x240 kopie.png
320 x 240 pixel resolution
The T400-Series has a thermal image resolution of 320 x 240 pixels.

sensitivity 1

Camera sensitivity
The FLIR T400-series has a thermal sensitivity of < 45 mK.

visual camera
High quality visual camera
Both models in the FLIR T400-Series have an integrated 3.1 Mpixel digital camera.
accurate non temp measurement
Measurement range
The T400-series can measure temperatures up to +1200°C.

lenses
Interchangeable infrared lenses
The T400-Series features a standard 25° lens and optional 6°, 15°, 45° and 90° lenses.

interchange lens
 
Flexible interfaces
The T400-Series is equipped with standard video, USB outputs as well as a removable SD card.

MPEG4
 
MPEG-4 video 
Create visual and infrared non radiometric MPEG-4 video files.

thermafusion
 
Thermal Fusion
Merges visual and thermal images to offer better analysis.

temperature alert
 
Temperature sound, image alarms 
Make surveying easier and faster.

PIP
 
Picture-in-Picture
Create an infrared overlay on your visual image. Scalable, moveable and resizable.

annotations_textvoicesket kopie.png
 
Text and voice annotations
Text comments can be made from a pre-defined list or using the touch screen. A headset can be connected to make voice annotations.

annotations_sketch kopie.png
 
Sketch annotations
Use the touch screen as pen and paper to add sketch annotations.

Imagesketch
 
Image sketch
Indicate problem areas directly on the thermal image.

video streaming
 
Radiometric IR video streaming 
16 bit radiometric IR video can be streamed to a PC (via USB) running the FLIR R&D software.

jpg
 
Image storage
FLIR uses a non proprietary radiometric JPEG image format that allows for post processing and report writing with Microsoft Word® based FLIR software.

touchscreen
 
Touch screen
3.5" LCD touch screen brings interactivity and user comfort to a new level.

measurement modes
 
Measurement Modes
Measurement spots, area with auto hot/cold spot indication, isotherms, ΔT calculation.

copy USB.png
 
Copy to USB
Transfer on board images or reports directly from the thermal imaging camera to a USB stick.

instant report
  
Instant reports
Create instant reports directly in camera, easily copy report to USB.

MSX
 
Multi Spectral Dynamic Imaging (MSX)
The innovative MSX feature produces an image more rich in every detail than ever before.

wifi
 
WiFi
Connect to smartphone or tablet via Wi-Fi, using the FLIR Tools mobile app (Apple iOS and Android) for processing and sharing results as well as for remote control.

  
 * Features dependant on camera model, please check technical specifications for more details.

FLIR T400-Series camera model comparison


FLIR T420FLIR T440
Temperature range: -20°C to +650ºCTemperature range: -20°C to +1,200ºC
4x continuous digital zoom8x continuous digital zoom
 MSX
 Image sketch on IR and visual
 Live line profile
 Measurement presets


Contact Us for more information

Thursday, 12 April 2012

ITC - Level 2 Thermography Courses



ITC_logo

The five day level 2 training course prepares you for qualification as a level 2 certified Thermographer.
You will learn about topics in Infrared Thermography to both deepen and broaden your knowledge about infrared physics, heat science, infrared measurement equipment and its application. As a Level 2 Thermographer you shall provide guidance to category 1 personnel in the areas of equipment selection, techniques, limitations, data analysis, corrective actions and reporting.
In order to attend a Level 2 Thermography Course, you shall
  • hold a valid Level 1 Thermography certificate.
  • prepare a case study to be presented at the Level 2 course and submittedtowards qualification at course closing. Details and guidelines on the case studywill be issued 2-3 weeks prior to the course start date.

Introduction to Thermography:

Review of Level 1 Thermography.

Temperature:

Conversion factors between Kelvin, Celsius, Fahrenheit.

Heat & Temperature:

Convection, conduction and radiation – Radiation Laws.

Thermography:

Blackbodies, emissivity. Planks, Boltzman, Newton, Wein’s laws Optical filters, optical materials, anti-reflective coatings.
Atmospheric transmission and attenuation. Detector technologies and calibration.
Measurement techniques.

IR Measurement Systems Overview:

Details of different thermal imaging camera parameters including, NETD, IFOV, MFOV

IR Windows and Window Materials:

Window measurement formulae, spectral transmittance of different materials.

Transient Thermographic NDT:

Transient Thermographic methods analysed.

ITC Certification Test:

ITC qualification test to be held on last day ofcourse.
Please bring with you a scientific calculator, your laptop with software loaded and your Thermal Imaging camera as they will be used extensively throughout the course. There will be some reading required during the evenings.

Recommended Reading

ASNT Level III Study Guide ISBN 1-57117-015-4
Common Sense Approach to Thermal Imaging ISBN 0-8194-3722-0
Infrared Thermography Principles & Practice ISBN 0903132338
Infrared Thermography Applications ISBN 090313232x
ISO 18434-1 Condition Monitoring and Diagnostics of Machines - Thermography
ISO 13372 Condition Monitoring and Diagnostics of Machines - Vocabulary

ITC Level 2 course dates for UK and Ireland for 2012
2nd to 6th July
ITC Level 2 Thermography
FLIR Office Kent
3rd to 7th December
ITC Level 2 Thermography
FLIR Office Kent
 Part Number:  ITC-CER-5201                                              Price  £ 1,785  +VAT
Full Payment is required for all training courses, prior to commencement of the course.
To find out the next available dates this course will be run and to book your place please contact us as soon as possible.

Wednesday, 14 March 2012

iLearnBalancing - Computer-based, Precision Field Balancing Training



iLearnBalancing

  NEW - iLearnBalancing Interactive field balancing training

 iLearnBalancing provides you with in-depth understanding of why balancing is so important as part of a condition monitoring and plant reliability program. It will help you understand how unbalance creates high forces that rob rolling element bearings of their full lifetime. You will understand the different types of unbalance, including static, couple and dynamic unbalance and what you need to do to correct them. It will also show you ways to ensure that you are not chasing the wrong solution; how to make sure that the machine is out of balance and it's not another fault condition with similar symptoms. Yes, there are many instruments that will walk you through a balance job as you acquire data, but they assume you know the nuances of balancing. With a deeper understanding of balancing, you won't waste time on machines that don't need to be balanced, the job will go more smoothly and you will be able to deal with any problems that come up during the balancing process.
Our 3D animations and simulators will make it more interesting to learn precision balancing and the course is fully narrated; you don't need to read it and it's easier to understand. We also include a number of interactive simulators so you can see the interaction between unbalance, rotational speed and phase, and work with vectors. The course uses both imperial and metric equations and measurement data. We cover multiple balancing methods, including single plane vector and program, two-plane program, overhung machines using single and two plane methods, static/couple, and four run, no-phase balancing. We also explain tolerances so that you know that the balance quality you achieve is good.
Contact Us for more information

Friday, 9 March 2012

Vibration Monitoring & Analysis Service


World Class Vibration Monitoring Service


Vibration ServiceAs a quality service provider, Proviso Systems offer custom designed vibration monitoring and analysis support packages for companies, both large and small. Our client list extends from major blue-chip corporations to SME's across a broad spectrum of industry including power generation, food, chemical, aerospace and manufacturing. We can also provide training for your operatives and, as an authorised distributor for some of the latest condition monitoring technology, we can supply a wide range of hardware, software, sensors and systems at highly competitive prices.
Whether you require information on our service contracts or would like assistance setting up your own condition monitoring program we have the expertise to help you in your endeavour.

Benefits of Vibration Monitoring

vibration_analyst
  1. Widely Applicable
  2. Consistent Across All Equipment
  3. Simple Data Comparison
  4. Early Problem Detection
  5. Strong Fault Diagnosis (Installation, Manufacture, Component & Lubrication etc)
  6. Walk around / Real Time & Online Data Acquisition
  7. ISO & Dynamic Alarm Set Points
  8. Increase Plant Uptime / Profits
  9. Extend Maintenance Periods / Reduce Spares Stock
  10. Improve Shutdown Scheduling

Vibration Monitoring Services Offered

Audits - We'll assess your plant and give recommedations and requirements.
In House Systems - We can asist you in the best way to setup and maintain your own in house vibration monitoring program.
Vibration Monitoring Service - Routine data collection, analysis and reporting carried out by us.
Vibration Analysis - You collect the data and we will analyse it and report back our findings.
Trouble Shoots - One off diagnosis and analysis of machine vibration problems.
Commissioning - A full vibration monitoring report prior to plant handover and acceptance.
System Setup - No matter whose product you have we can assist in setup and best practice.
Balancing - We can balance machinery in-situ.
Seismic Monitoring - We can monitor for undesirable or excessive vibration during demolition / construction etc.